небаланс напряжения

  • 1 voltage unbalance

    1. несимметрия напряжений
    2. небаланс напряжения
    3. небаланс напряжений

     

    небаланс напряжений
    Отличие по модулю значения хотя бы одного из фазных или линейных напряжений многофазной системы электроснабжения от значений напряжений других фаз.
    [ ГОСТ 23875-88]

    EN

    voltage unbalance
    phenomenon due to the differences between voltage deviations on the various phases, at a point of a polyphase system, resulting from differences between the phase currents or geometrical asymmetry in the line
    [IEV number 604-01-29]

    voltage unbalance (imbalance)
    in a polyphase system, a condition in which the magnitudes of the phase voltages or the phase angles between consecutive phases are not all equal (fundamental component)
    NOTE In three phase systems, the degree of inequality is usually expressed as the ratio of the negative and zero sequence components to the positive sequence component. In this technical report, voltage unbalance is considered in relation to three-phase systems and negative sequence only
    [IEC 61000-3-13, ed. 1.0 (2008-02)]

    voltage unbalance
    condition in a polyphase system in which the r.m.s. values of the line voltages (fundamental component), and/or the phase angles between consecutive line voltages, are not all equal
    NOTE 1 The degree of the inequality is usually expressed as the ratios of the negative- and zero-sequence components to the positive-sequence component.
    NOTE 2 In this standard, voltage unbalance is considered in relation to 3-phase systems.
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    déséquilibre des tensions d'un réseau
    phénomène résultant des différences de charge ou des dissymétries géométriques de lignes et qui provoque des différences entre les écarts de tension sur les diverses phases en un point d'un réseau polyphasé
    [IEV number 604-01-29]

    déséquilibre de tension
    dans un réseau d’énergie électrique polyphasé, état dans lequel les valeurs efficaces des tensions entre conducteurs (composante fondamentale), et/ou les différences de phase entre conducteurs successifs, ne sont pas toutes égales
    NOTE 1 Le taux de déséquilibre s’exprime habituellement par le rapport de la composante inverse ou homopolaire à la composante directe.
    NOTE 2 Dans la présente norme, le déséquilibre de tension est relatif aux réseaux triphasés
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Параллельные тексты EN-RU

    4748       4749      4750

    Voltage unbalance
    Voltage unbalance on the most unbalanced phase, displayed as a percentage of Vavg.

    [Schneider Electric]

    Небаланс напряжений
    Самое значительное отличие по модулю значения одного из линейных напряжений, выраженное в процентах от среднего напряжения Vavg.

    [Перевод Интент]


    Недопустимые, нерекомендуемые

    Тематики

    EN

    DE

    FR

    Смотри также

     

    несимметрия напряжений
    Состояние системы энергоснабжения трехфазного переменного тока, в которой среднеквадратические значения основных составляющих междуфазных напряжений или углы сдвига фаз между основными составляющими междуфазных напряжений не равны между собой.
    Примечания
    1 Степень несимметрии обычно выражают отношением напряжений обратной и нулевой последовательностей к напряжению прямой последовательности.
    2 В настоящем стандарте несимметрия напряжений рассматривается применительно только к трехфазным системам энергоснабжения.
    [ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]

    EN

    voltage unbalance
    condition in a polyphase system in which the r.m.s. values of the line voltages (fundamental component), and/or the phase angles between consecutive line voltages, are not all equal
    NOTE 1 The degree of the inequality is usually expressed as the ratios of the negative- and zero-sequence components to the positive-sequence component.
    NOTE 2 In this standard, voltage unbalance is considered in relation to 3-phase systems.
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    déséquilibre de tension
    dans un réseau d’énergie électrique polyphasé, état dans lequel les valeurs efficaces des tensions entre conducteurs (composante fondamentale), et/ou les différences de phase entre conducteurs successifs, ne sont pas toutes égales
    NOTE 1 Le taux de déséquilibre s’exprime habituellement par le rapport de la composante inverse ou homopolaire à la composante directe.
    NOTE 2 Dans la présente norme, le déséquilibre de tension est relatif aux réseaux triphasés.
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Тематики

    EN

    FR

    3.34 несимметрия напряжений (voltage unbalance): Состояние системы энергоснабжения трехфазного переменного тока, в которой среднеквадратические значения основных составляющих междуфазных напряжений или углы сдвига фаз между основными составляющими междуфазных напряжений не равны между собой.

    Примечания

    1 Степень несимметрии обычно выражают отношением напряжений обратной и нулевой последовательностей к напряжению прямой последовательности.

    2 В настоящем стандарте несимметрия напряжений рассматривается применительно только к трехфазным системам энергоснабжения.

    3.35 установившееся отклонение напряжения: Разность между среднеквадратическим значением напряжения основной частоты в системе электроснабжения, определенным на установленном интервале времени, и номинальным значением напряжения.

    3.36


    Источник: ГОСТ Р 51317.4.30-2008: Электрическая энергия. Совместимость технических средств электромагнитная. Методы измерений показателей качества электрической энергии оригинал документа

    3.2.11 небаланс напряжения (voltage unbalance); δU2,0: Соотношение составляющей отрицательной или нулевой последовательности и составляющей положительной последовательности при холостом ходе, выражаемое в процентах номинального напряжения.

    Источник: ГОСТ Р 53986-2010: Электроагрегаты генераторные переменного тока с приводом от двигателя внутреннего сгорания. Часть 3. Генераторы переменного тока оригинал документа

    Англо-русский словарь нормативно-технической терминологии > voltage unbalance

  • 2 imbalance in the voltages

    1. небаланс напряжений

     

    небаланс напряжений
    Отличие по модулю значения хотя бы одного из фазных или линейных напряжений многофазной системы электроснабжения от значений напряжений других фаз.
    [ ГОСТ 23875-88]

    EN

    voltage unbalance
    phenomenon due to the differences between voltage deviations on the various phases, at a point of a polyphase system, resulting from differences between the phase currents or geometrical asymmetry in the line
    [IEV number 604-01-29]

    voltage unbalance (imbalance)
    in a polyphase system, a condition in which the magnitudes of the phase voltages or the phase angles between consecutive phases are not all equal (fundamental component)
    NOTE In three phase systems, the degree of inequality is usually expressed as the ratio of the negative and zero sequence components to the positive sequence component. In this technical report, voltage unbalance is considered in relation to three-phase systems and negative sequence only
    [IEC 61000-3-13, ed. 1.0 (2008-02)]

    voltage unbalance
    condition in a polyphase system in which the r.m.s. values of the line voltages (fundamental component), and/or the phase angles between consecutive line voltages, are not all equal
    NOTE 1 The degree of the inequality is usually expressed as the ratios of the negative- and zero-sequence components to the positive-sequence component.
    NOTE 2 In this standard, voltage unbalance is considered in relation to 3-phase systems.
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    déséquilibre des tensions d'un réseau
    phénomène résultant des différences de charge ou des dissymétries géométriques de lignes et qui provoque des différences entre les écarts de tension sur les diverses phases en un point d'un réseau polyphasé
    [IEV number 604-01-29]

    déséquilibre de tension
    dans un réseau d’énergie électrique polyphasé, état dans lequel les valeurs efficaces des tensions entre conducteurs (composante fondamentale), et/ou les différences de phase entre conducteurs successifs, ne sont pas toutes égales
    NOTE 1 Le taux de déséquilibre s’exprime habituellement par le rapport de la composante inverse ou homopolaire à la composante directe.
    NOTE 2 Dans la présente norme, le déséquilibre de tension est relatif aux réseaux triphasés
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Параллельные тексты EN-RU

    4748       4749      4750

    Voltage unbalance
    Voltage unbalance on the most unbalanced phase, displayed as a percentage of Vavg.

    [Schneider Electric]

    Небаланс напряжений
    Самое значительное отличие по модулю значения одного из линейных напряжений, выраженное в процентах от среднего напряжения Vavg.

    [Перевод Интент]


    Недопустимые, нерекомендуемые

    Тематики

    EN

    DE

    FR

    Смотри также

    Англо-русский словарь нормативно-технической терминологии > imbalance in the voltages

  • 3 unbalance voltage

    1. небаланс напряжений

     

    небаланс напряжений
    Отличие по модулю значения хотя бы одного из фазных или линейных напряжений многофазной системы электроснабжения от значений напряжений других фаз.
    [ ГОСТ 23875-88]

    EN

    voltage unbalance
    phenomenon due to the differences between voltage deviations on the various phases, at a point of a polyphase system, resulting from differences between the phase currents or geometrical asymmetry in the line
    [IEV number 604-01-29]

    voltage unbalance (imbalance)
    in a polyphase system, a condition in which the magnitudes of the phase voltages or the phase angles between consecutive phases are not all equal (fundamental component)
    NOTE In three phase systems, the degree of inequality is usually expressed as the ratio of the negative and zero sequence components to the positive sequence component. In this technical report, voltage unbalance is considered in relation to three-phase systems and negative sequence only
    [IEC 61000-3-13, ed. 1.0 (2008-02)]

    voltage unbalance
    condition in a polyphase system in which the r.m.s. values of the line voltages (fundamental component), and/or the phase angles between consecutive line voltages, are not all equal
    NOTE 1 The degree of the inequality is usually expressed as the ratios of the negative- and zero-sequence components to the positive-sequence component.
    NOTE 2 In this standard, voltage unbalance is considered in relation to 3-phase systems.
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    déséquilibre des tensions d'un réseau
    phénomène résultant des différences de charge ou des dissymétries géométriques de lignes et qui provoque des différences entre les écarts de tension sur les diverses phases en un point d'un réseau polyphasé
    [IEV number 604-01-29]

    déséquilibre de tension
    dans un réseau d’énergie électrique polyphasé, état dans lequel les valeurs efficaces des tensions entre conducteurs (composante fondamentale), et/ou les différences de phase entre conducteurs successifs, ne sont pas toutes égales
    NOTE 1 Le taux de déséquilibre s’exprime habituellement par le rapport de la composante inverse ou homopolaire à la composante directe.
    NOTE 2 Dans la présente norme, le déséquilibre de tension est relatif aux réseaux triphasés
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Параллельные тексты EN-RU

    4748       4749      4750

    Voltage unbalance
    Voltage unbalance on the most unbalanced phase, displayed as a percentage of Vavg.

    [Schneider Electric]

    Небаланс напряжений
    Самое значительное отличие по модулю значения одного из линейных напряжений, выраженное в процентах от среднего напряжения Vavg.

    [Перевод Интент]


    Недопустимые, нерекомендуемые

    Тематики

    EN

    DE

    FR

    Смотри также

    Англо-русский словарь нормативно-технической терминологии > unbalance voltage

  • 4 voltage imbalance

    1. неуравновешенность напряжений
    2. небаланс напряжений

     

    небаланс напряжений
    Отличие по модулю значения хотя бы одного из фазных или линейных напряжений многофазной системы электроснабжения от значений напряжений других фаз.
    [ ГОСТ 23875-88]

    EN

    voltage unbalance
    phenomenon due to the differences between voltage deviations on the various phases, at a point of a polyphase system, resulting from differences between the phase currents or geometrical asymmetry in the line
    [IEV number 604-01-29]

    voltage unbalance (imbalance)
    in a polyphase system, a condition in which the magnitudes of the phase voltages or the phase angles between consecutive phases are not all equal (fundamental component)
    NOTE In three phase systems, the degree of inequality is usually expressed as the ratio of the negative and zero sequence components to the positive sequence component. In this technical report, voltage unbalance is considered in relation to three-phase systems and negative sequence only
    [IEC 61000-3-13, ed. 1.0 (2008-02)]

    voltage unbalance
    condition in a polyphase system in which the r.m.s. values of the line voltages (fundamental component), and/or the phase angles between consecutive line voltages, are not all equal
    NOTE 1 The degree of the inequality is usually expressed as the ratios of the negative- and zero-sequence components to the positive-sequence component.
    NOTE 2 In this standard, voltage unbalance is considered in relation to 3-phase systems.
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    déséquilibre des tensions d'un réseau
    phénomène résultant des différences de charge ou des dissymétries géométriques de lignes et qui provoque des différences entre les écarts de tension sur les diverses phases en un point d'un réseau polyphasé
    [IEV number 604-01-29]

    déséquilibre de tension
    dans un réseau d’énergie électrique polyphasé, état dans lequel les valeurs efficaces des tensions entre conducteurs (composante fondamentale), et/ou les différences de phase entre conducteurs successifs, ne sont pas toutes égales
    NOTE 1 Le taux de déséquilibre s’exprime habituellement par le rapport de la composante inverse ou homopolaire à la composante directe.
    NOTE 2 Dans la présente norme, le déséquilibre de tension est relatif aux réseaux triphasés
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Параллельные тексты EN-RU

    4748       4749      4750

    Voltage unbalance
    Voltage unbalance on the most unbalanced phase, displayed as a percentage of Vavg.

    [Schneider Electric]

    Небаланс напряжений
    Самое значительное отличие по модулю значения одного из линейных напряжений, выраженное в процентах от среднего напряжения Vavg.

    [Перевод Интент]


    Недопустимые, нерекомендуемые

    Тематики

    EN

    DE

    FR

    Смотри также

     

    неуравновешенность напряжений
    асимметрия напряжений (многофазной системы)


    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    Англо-русский словарь нормативно-технической терминологии > voltage imbalance

  • 5 voltage unbalance

    Универсальный англо-русский словарь > voltage unbalance

  • 6 double conversion UPS

    1. источник бесперебойного питания с двойным преобразованием (энергии)

     

    источник бесперебойного питания с двойным преобразованием (энергии)
    -

    EN

    double conversion
    Topology of On-Line UPS (VFI class per IEC 62040-3). The AC mains voltage is converted to DC by means of an ac to DC Rectifier (or Charger), The DC voltage is then converted to conditioned AC by means of the Inverter.
    [ http://www.upsonnet.com/UPS-Glossary/]

    0423
    Структурная схема ИБП с двойным преобразованием энергии

    Вся потребляемая из питающей сети энергия поступает на выпрямитель и преобразуется в энергию постоянного тока, а затем инвертором - в энергию пере­менного тока.

    Высококачественные ИБП с двойным преобразованием энергии, как правило, имеют гальваническую развязку, что значительно улучшает помехоустойчивость защищаемого оборудования.

    Обязательным элементом ИБП двойного преобразования большой и средней мощности является байпас - устройство обходного пути. Байпас представляет собой комбинированное электронно-механическое устрой­ство, состоящее из так называемого статического байпаса и ручного (механическо­го, контактного) байпаса.

    Достоинства

    • Нулевое время переключения.
      В некоторых случаях данный фактор в настоящее время перестал играть решающую роль, потому что в современных компьютерах применяются блоки питания, соответствующие стандартам IEEE, согласно которым компьютер должен быть способен выдерживать перерыв в питании не менее 8.3 мс.
      При этом в off-line ИБП, выпускаемых фирмой АРС время переключения не превышает 8 мс.
    • Строгая стабилизация выходного напряжения.

    Недостатки

    • Высокая стоимость,
    • Повышенный уровень помех, вносимых самим ИБП в электрическую сеть,
    • Более низкий КПД по сравнению с другими типами ИБП.

    [ http://www.tcs.ru/reviews/?id=345 с изменениями]


    Часто в качестве синонима термина ИПБ с двойным преобразованием употребляют термин on-line ИБП. Это не верно, так как в группу on-line ИБП входят ИБП четырех типов (см. источник бесперебойного питания активного типа).

    В ИБП с двойным преобразованием вся потребляемая энергия поступает на выпрямитель и преобразуется в энергию постоянного тока, а затем инвертором — в энергию пере­менного тока.

    Технология двойного преобразования отработана и успешно используется свы­ше двадцати лет, однако ей присущи принципиальные недостатки:

    • ИБП является причиной гармонических искажений тока в электрической сети (до 30%) и, таким образом, — потенциально причиной нарушения работы другого оборудования, соединенного с электрической сетью; он имеет низкое значение входного коэффициента мощности (coscp);
    • ИБП имеет значительные потери, так как принципом получения выходного переменного тока является первичное преобразование в энергию постоянного тока, а затем снова преобразование в энергию переменного тока; в процессе такого двойного преобразования обычно теряется до 10 % энергии.

    Первый недостаток устраняется за счет применения дополнительных уст­ройств (входных фильтров, 12-импульсных выпрямителей, оптимизаторов-бусте­ров), а второй принципиально не устраним (у лучших образцов ИБП большой мощности КПД не превышает 93 %).

    Современные ИБП двойного преобразования оборудуются так называемыми кондиционерами гармоник и устройствами кор­рекции коэффициента мощности (coscp). Эти устройства входят либо в базовый комплект ИБП, либо применяются опционально и позволяют снять проблему с внесением гармонических искажений (составляют не более 3 %) и повысить коэф­фициент мощности до 0,98.

    Существуют схемы ИБП с двойным преобразованием 1:1, 3:1 и 3:3. Это означает:

    • 1:1 — однофазный вход, однофазный выход;
    • 3:1 — трехфазный вход, однофазный выход;
    • 3:3 — трехфазный вход, трехфазный выход.

    Схемы 1:1 и 3:1 целесообразно применять для мощностей нагрузки до 30 кВА, при этом симметрирование не требуется, и мощность инвертора используется ра­ционально. Следует иметь в виду, что байпас в таких схемах является однофазным и при переходе ИБП с инвертора на байпас для входной сети ИБП 3:1 становится несимметричным устройством, подобно ИБП 1:1.

    0429
    ИБП по схеме 3:1

    Особенностью данной схемы является наличие на входе конвертора 3:1. При его отсутствии ИБП имеет схему 1:1. Наличие конвертора не только превращает ИБП 1:1 в 3:1, но и позволяет осуществлять работу через байпас в симметричном режиме.

    0430
    ИБП по схеме 3:3

    ИБП по схеме 3:3 в отличие от ИПБ по схеме 3:1 имеет зарядное устройство для оптимизации режима заряда аккумулятор­ной батареи и преобразователь постоянного тока — бустер (booster DC/DC), позво­ляющий облегчить работу выпрямителя за счет снижения глубины регулирования. Таким образом обеспечивается меньший уровень гармонических искажений вход­ного тока. В некоторых случаях такую схему называют схемой с тройным преобра­зованием.

    Принципиально нет предпосылок выделять такие схемы в отдельный тип ИБП, так как остается общим главный принцип — выпрямление тока с его последующим инвертированием. Разумеется, в звене постоянного тока могут присутствовать сгла­живающие ёмкости, а в некоторых случаях — дроссель (на схемах не показаны). ИБП  работает по схеме 3:3 в любом режиме — при работе через инвертор (ре­жим on-line) и при работе через байпас. По отношению к питающей сети работа в ре­жиме on-line является симметричной, тогда как работа через байпас зависит от балан­са нагрузок по фазам. Впрочем, сбалансированность нагрузок по фазам в первую очередь важна для рационального использования установленной мощности самого источника, а по отношению к питающей сети небаланс по фазам при работе через бай­пас может проявить себя только при работе с ДГУ. Но в этом случае решающим будет не симметрия нагрузки, а её нелинейность.

    [ http://electromaster.ru/modules/myarticles/article.php?storyid=365 с изменениями]

    Тематики

    Обобщающие термины

    Синонимы

    EN

    Англо-русский словарь нормативно-технической терминологии > double conversion UPS

См. также в других словарях:

  • небаланс напряжения — 3.2.11 небаланс напряжения (voltage unbalance); δU2,0: Соотношение составляющей отрицательной или нулевой последовательности и составляющей положительной последовательности при холостом ходе, выражаемое в процентах номинального напряжения.… …   Словарь-справочник терминов нормативно-технической документации

  • Небаланс — разница между количеством вещества, поступившим в трубопроводную сеть и отобранным из нее участниками коммерческого учета (Unaccounted for gas) за сутки или за отчетный период. Источник …   Словарь-справочник терминов нормативно-технической документации

  • небаланс напряжений — Отличие по модулю значения хотя бы одного из фазных или линейных напряжений многофазной системы электроснабжения от значений напряжений других фаз. [ГОСТ 23875 88] EN voltage unbalance phenomenon due to the differences between voltage deviations… …   Справочник технического переводчика

  • характеристики регулирования напряжения — 3.2.12 характеристики регулирования напряжения: Кривые напряжения на выводах генератора как функции токов нагрузки при заданном коэффициенте мощности в установившемся режиме при номинальной частоте вращения без какого либо ручного управления… …   Словарь-справочник терминов нормативно-технической документации

  • ГОСТ Р 53986-2010: Электроагрегаты генераторные переменного тока с приводом от двигателя внутреннего сгорания. Часть 3. Генераторы переменного тока — Терминология ГОСТ Р 53986 2010: Электроагрегаты генераторные переменного тока с приводом от двигателя внутреннего сгорания. Часть 3. Генераторы переменного тока оригинал документа: 3.2.9 время восстановления напряжения (voltage recovery time); tU …   Словарь-справочник терминов нормативно-технической документации

  • Характеристики — К.4. Характеристики Применяют следующие дополнительные характеристики: К.4.3.1.2. Номинальное напряжение изоляции Минимальное значение номинального напряжения изоляции должно быть 250 В. К.4.3.2.1. Условный тепловой ток на открытом воздухе… …   Словарь-справочник терминов нормативно-технической документации

  • ГОСТ 23875-88: Качество электрической энергии. Термины и определения — Терминология ГОСТ 23875 88: Качество электрической энергии. Термины и определения оригинал документа: Facteur de distortion (d’une tension ou d’un courant alternatif non sinusoïdal) 55 Определения термина из разных документов: Facteur de… …   Словарь-справочник терминов нормативно-технической документации

  • ГОСТ Р 54130-2010: Качество электрической энергии. Термины и определения — Терминология ГОСТ Р 54130 2010: Качество электрической энергии. Термины и определения оригинал документа: Amplitude die schnelle VergroRerung der Spannung 87 Определения термина из разных документов: Amplitude die schnelle VergroRerung der… …   Словарь-справочник терминов нормативно-технической документации

  • статическая — 3.7 статическая нагрузка: Внешнее воздействие, которое не вызывает ускорений деформируемых масс и сил инерции. Источник …   Словарь-справочник терминов нормативно-технической документации

  • источник бесперебойного питания с двойным преобразованием (энергии) — EN double conversion Topology of On Line UPS (VFI class per IEC 62040 3). The AC mains voltage is converted to DC by means of an ac to DC Rectifier (or Charger), The DC voltage is then converted to conditioned AC by means of the Inverter.… …   Справочник технического переводчика

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»